Kaifeng, China · Flow measurement & instrumentation
Hui Ma
Flow measurement engineer · Henan SIKE Measurement & Control Technology Co., Ltd.
Selection calculation, calibration and technical documentation for orifice plates, throttling devices and electromagnetic flowmeters. I work on the engineering side of the job: β, ReD, ε, pressure loss and uncertainty — each one traced back to the standard it comes from.
What I do
Engineering services
Solutions are built per model; the technical points come from measured data, current standards and our own baseline.
Selection & calculation
Specification checking and calculation for orifice plates, throttling devices, electromagnetic flowmeters and level instruments — selection sheets, data sheets and device drawings.
Calibration & comparison
Large-bore flow calibration capability: meter comparison and the related technical documentation, including the supporting material for large-bore calibration work.
Technical documentation
Selection experience, standards and product data turned into searchable, reusable documents — in Chinese, English and other languages.
Documents for tenders
Technical documents, product descriptions and selection reports prepared per customer, multilingual and ready for a bid package.
Tools
Selection calculators
Computed with the GB/T 2624 (ISO 5167) equations, then checked against the limits of the standard. This is for checking a proposal you already hold — parameters a supplier quoted, evidence an inspector asks for. The formal design comes with a calculation sheet from us.
Throttling device calculator
Orifice plate, Venturi tube, nozzle, cone and wedge devices: flow from Δp, or Δp from flow — plus C, ε, ReD, pressure loss and δC/C.
Open → 02Electromagnetic flowmeter lookup
Pick the DN from the maximum process flow, see the recommended range and the maximum measurable flow, and check velocity, range setting and straight-run conditions.
Open → 03Velocity & Reynolds number
From a flow and a pipe diameter: velocity, mass flow and ReD — and which device family that duty actually falls into.
Open →Articles
Technical notes
The clauses most often skipped, turned into conclusions you can use — with the clause reference attached.
Five hard limits of orifice plate selection
d ≥ 12.5 mm, 50 ≤ D ≤ 1000 mm, 0.1 ≤ β ≤ 0.75, ReD ≥ 5000 and τ ≥ 0.75 — cross one of them and the equation stops being valid.
Read →Electromagnetic flowmeter: DN and range
Set the range to the maximum flow, not the average; how to use the 1 m/s table and the recommended range, plus straight run and conductivity preconditions.
Read →Not enough straight run?
The A and B columns, the 0.5% additional uncertainty, flow conditioners — and the engineering compromise of the integral orifice flow meter.
Read →Products
What we build and supply
Orifice plates and throttling devices, electromagnetic flowmeters, radar and magnetic level gauges and other flow instruments; Siemens process instruments are supplied alongside, with selection data, datasheets and quotation per model.
Our products & capability
Differential pressure & throttling devices
Orifice plates, ISA 1932 nozzles, Venturi tubes, cone and wedge devices; corner, D-D/2 and flange taps; integral orifice assemblies per JB/T 7252.
Open throttling device calculator →
Electromagnetic flowmeters
SKLD series: integral type EH and remote type ER, built to JB/T 9248-1999. Liner, electrodes, range and mounting are set against the medium, temperature, pressure and conductivity, with straight-run lengths given together.
Open EM flowmeter lookup →
Magnetic level gauges
Magnetic flap level gauges, supplied as actual products: structure, range, wetted materials and flanges are set against the medium and the vessel, with optional 4-20 mA transmission and high/low alarms.
See magnetic level gauges →
Calibration & comparison
Large-bore calibration facility (DN10 to DN1400, water): meter comparison data and the related technical descriptions, together with on-site installation and commissioning.
See calibration scope →Siemens process instruments
Electromagnetic flowmeters
SITRANS FMS300 in remote and integral versions: liner and electrode materials matched to temperature, pressure and corrosiveness, with range setting, straight-run and conductivity checks.
Send the duty for a quotation →
Pressure transmitters
SITRANS P320 / P420 smart pressure transmitters: range, accuracy, overpressure capability and wetted materials matched to the duty; differential pressure transmitters checked the same way.
Send the duty for a selection sheet →
Radar level transmitters
SITRANS LR500 radar level transmitters: antenna type, range and mounting arranged against the vessel and the medium, with continuous measurement, alarms and companion instruments.
See level selection →
Coriolis mass flowmeters
SITRANS FC series in integral and remote mounting versions: range, density and viscosity compensation set against the medium, with zeroing and configuration carried out with the instrument.
Send the duty for a selection sheet →Contact
Send the duty data
Price and commercial terms are quoted per model. With complete duty data the selection sheet and quotation can go out the same day.
- Email: mhui6676@gmail.com
- Telegram: @sike_flowmeter_cn
- Address: No.11 Wei Du Road & 11th Street Intersection (North), Kaifeng, Henan, China
- Company: Henan SIKE Measurement & Control Technology Co., Ltd.
Information on this site is prepared for engineering estimation and first-stage selection. Supply is governed by the technical agreement and drawings confirmed by both parties.