The clauses most often skipped, turned into conclusions you can use — each one with its source attached. Written for the field and the selection desk, not as a summary of standards.
GB/T 2624.2
Five hard limits of orifice plate selection
d ≥ 12.5 mm, 50 ≤ D ≤ 1000 mm, 0.1 ≤ β ≤ 0.75, ReD ≥ 5000, τ ≥ 0.75. Cross one of them and the discharge coefficient equation stops being valid.
Read →SKLD electromagnetic flowmeter
EM flowmeter: choosing DN and range
Set the range to the maximum flow, not the average. The 1 m/s table, the recommended range, and the straight run and conductivity preconditions.
Read →GB/T 2624.1 · JB/T 7252
Not enough straight run?
The A and B columns and the 0.5% additional uncertainty, how to choose a flow conditioner, and the integral orifice flow meter as an engineering compromise.